English Chinese Simplified Chinese Traditional French German Portuguese Spanish Russian Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Leave Your Message

KWS Keel Heavy-Duty Primary Air Filtration Unit

Model Number KWS-001 AIR filter
Color White&Green
Dimensions Customized
Net Weight Customized
Material The outer frame is made of aluminium or galvanised frame
Applications Air purifier filters
Brand Name KWS or OEM
Origin Xiamen, China (mainland)

    Product Introduction

    The keel primary filter is the first line of defence in an air purification system and is mainly used to intercept large particles of airborne pollutants such as dust, hair, fibres and pollen. The core structure consists of a metal keel frame and a synthetic fibre filter media. The frame is robust and durable, while the filter mesh achieves high efficiency interception through a multi-layer interlocking design, while maintaining a low wind resistance to ensure smooth air flow.
    These filters are widely used in commercial and industrial scenarios, such as:
    1.Central air-conditioning systems: to protect back-end precision equipment (e.g., high-efficiency filters, fans) and extend service life;
    2.Cleanrooms and laboratories: pre-filter suspended particles to maintain cleanliness;
    3.Hospitals and pharmaceutical factories: reducing bacterial vectors and assisting in controlling the risk of cross-infection;
    4.Factory workshops: blocking dust, improving the working environment and protecting production equipment.
    The advantages of keel primary filters are high dust capacity, low cost and easy to replace, usually need to be cleaned or replaced every 3-6 months (depending on the amount of dust in the environment). When selecting a filter, it is important to look at the filtration rating (e.g. G3-G4 standard) and size suitability to ensure compatibility with existing systems. Proper use can significantly improve air quality and reduce operation and maintenance costs.

    Product Characteristics

    1.The outer frame is made of aluminium or galvanised frame, with a unique supporting skeleton structure (sub-mother frame), which makes the filter media multi-pleated and shaped.
    2.Easy to replace and assemble, good versatility, and stronger stability.
    3.The filter media is made of high quality polyester synthetic fibre with low initial resistance and good fireproof performance. 
    4.At the end of use, the filter media can be replaced or cleaned and reused, which can effectively reduce operating costs.
    Filter efficiency
    G3(EN779), MERV6(ASHRAE52.2)
    G4(EN779), MERV8(ASHRAE52.2)

    Technical Parameter

    Name Size Rated airflow Efficiency Initial resistance Suggested ultimate resistance
    KWS-001 595*595*46 3600m³/h G4(35%) ≦65Pa ≦130Pa
    KWS-002 295*595*46 1500m³/h G4(35%) ≦65Pa ≦130Pa
    KWS-003 495*595*46 3200m³/h G4(35%) ≦65Pa ≦130Pa
    KWS-004 495*495*46 3000m³/h G4(35%) ≦65Pa ≦130Pa

    Applications

    1.Pre-filtering of general air conditioning and ventilation systems to avoid the accumulation of dust and contamination within the system.
    2.Pre-filtration for large air compressors
    3.Centralised ventilation and air-conditioning systems for clean rooms and return air filtration, to extend the service life of high-efficiency filters at the back stage.
    4.Pre-filtration of general industrial plant ventilation systems to achieve general clean air requirements
    5.Pre-filtration of air-conditioning systems in general construction buildings
    6.Pre-filtration of ventilation and air-conditioning systems in public infrastructure for rail transport.