English Chinese Simplified Chinese Traditional French German Portuguese Spanish Russian Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Leave Your Message

KWS Primary Effect Panel Folding Air Filter

Model Number KWS-005AIR filter
Color White
Dimensions Customized
Net Weight Customized
Material Galvanised iron, polyester synthetic fibre
Applications Air purifier filters
Brand Name KWS or OEM
Origin Xiamen, China (mainland)

    Product Introduction

    Primary filters: the first line of defence in air purification
    As the critical first-stage defense in air purification systems, primary filters employ mechanical filtration to capture airborne contaminants exceeding 5 microns, including particulate matter, lint strands, fibrous debris, and allergenic pollen grains. Positioned at the filtration sequence forefront, these pre-filters strategically safeguard downstream precision filtration components (particularly HEPA modules) from premature particulate overload, thereby optimizing system longevity through reduced maintenance frequency and enhanced energy efficiency.
    In industrial workshops, commercial buildings and domestic air conditioning, the need for primary filters is reflected in three ways:
    1. Economy: This strategic pre-filtration solution achieves 60-80% particulate retention efficiency for ASHRAE-defined coarse particulates (≥3μm), thereby minimizing operational downtime for downstream HEPA/ULPA filter maintenance cycles. The optimized performance translates to measurable cost savings through extended filter lifespan management and reduced consumables expenditure;
    2. Efficiency guarantee: This engineered clogging mitigation mechanism effectively blocks particulate ingress (≥5μm) at the primary filtration interface, preserving structural porosity of HEPA-grade filtration media. Through sustained particulate load management, the system ensures ±2% airflow differential pressure stability and >99% contaminant removal efficacy retention over 10,000 operational hours;
    3. Widely applicable: washable or replaceable metal mesh, chemical fibre materials are suitable for scenes with high dust concentration (e.g. building ventilation, factory pre-treatment).
    According to statistics, without the installation of primary filter purification equipment, high-efficiency filter element life shortened by more than 40% on average. Whether it is to protect precision instruments or to improve indoor air quality, primary filters have become an indispensable cornerstone of modern air management with their low-cost and cost-effective features.

    Product Characteristics

    1. Cheap, light weight, good versatility, reduce operating costs;
    2. The outer frame is made of galvanised frame or aluminium frame, and the filter material is made of high-quality polyester synthetic fibre attached with rhombic mesh or welded wire mesh folded and shaped.
    3. Compact structure, commonly used in the ventilation system of the first level of filtration.
    4. It is also suitable for air-conditioning and ventilation system which only needs one level of filtration.
    Filter efficiency
    G3(EN779), MERV6(ASHRAE52.2)
    G4(EN779), MERV8(ASHRAE52.2)

    Technical Parameter

    Size Rated airflow efficiency initial resistance Suggested ultimate resistance
    595*595*46 3000m³/h G4(35%) ≦55Pa ≦110Pa
    295*595*46 1500m³/h G4(35%) ≦55Pa ≦110Pa
    595*595*96 3800m³/h G4(35%) ≦55Pa ≦110Pa
    295*595*96 1900m³/h G4(35%) ≦55Pa ≦110Pa
    Special sizes and specifications can be made according to customer requirements.

    Applications

    1. Pre-filtration of general air-conditioning and ventilation systems to avoid the accumulation of dust and pollution within the system.
    2. Pre-filtration of large air compressor.
    3. Centralized ventilation and air-conditioning systems and return air filtration in clean rooms to prolong the service life of high-efficiency filters at the back stage.
    4. Pre-filtration of general industrial plant ventilation system to achieve general clean air requirements.